Size | DFS-2 | DFS-3 |
Media | liquid | liquid |
Flow range | 0.07 – 2.0 L/min | 0.66 – 16.0 L/min |
Accuracy | ± 0.5% of reading | ± 0.5% of reading |
Linearity deviation | 0.5% | 0.5% |
Repeatability | < 0.15% | < 0.10% |
Average K-factor | 65,000 pulses/L | 4,400 pulses/L |
Operational temperature range | -20 to +85 °C | -20 to +85 °C |
Static temperature range | -20 to +130 °C | -20 to +130 °C |
Viscosity range | 0.8 - 10 cSt | 0.8 - 15 cSt |
Maximum pressure | 50 Bar | 50 Bar |
Pressure drop | 0.2 bar @ 1 L/m | 0.2 bar @ 5 L/m |
Power supply | 5 VDC, 12 - 36 mAmp | 5 VDC, 12 - 36 mAmp |
Output signal | 5 VDC square wave | 5 VDC square wave |
Rotor assembly material | PVDF | PVDF |
Housing material | PVDF / Stainless Steel 316L | PVDF / Stainless Steel 316L |
O-rings material | Viton | Viton |
Electrical lead | 1 meter | 1 meter |
Dimensions in length | 63.3 mm | 74 mm |
Dimensions in diameter | 21 mm | 44 mm |
Connections | 1/4” NPT or 1/4" BSP | 1/4” NPT or 1/4" BSP |
DFS Stainless Steel Flowmeter
- Engineering support available
- Over 20 year experience in flow measurement solutions
- Excellent price-quality
Certificates
Cable options
Please note; Add as many cable options as flowmetersCable extensions
Please note; Add as many cable extensions as flowmeters-